相關文章 / ARTICLE
描述:上海移動(dong)式耐壓(ya)(ya)儀廠家,可用來檢(jian)測有(you)關電氣裝置、電氣元件、電氣材料(liao)的抗電強度(du)及漏電情況。適(shi)用于中小型(xing)電機、高壓(ya)(ya)電機、低壓(ya)(ya)電器(qi)等產品(pin)的檢(jian)測。具有(you)電壓(ya)(ya)、電流(liu)數字顯示、擊穿聲光報警、自動(dong)斷開高壓(ya)(ya)、手動(dong)復位、漏電流(liu)直(zhi)接在高壓(ya)(ya)端(duan)測量(liang)等特點。
標題:上海移動式耐壓儀廠家
產品概述
產品概述:
上海移動式耐壓儀廠家,可用來(lai)檢(jian)(jian)測有關電(dian)(dian)(dian)(dian)氣裝置、電(dian)(dian)(dian)(dian)氣元(yuan)件、電(dian)(dian)(dian)(dian)氣材料的(de)抗(kang)電(dian)(dian)(dian)(dian)強度及(ji)漏電(dian)(dian)(dian)(dian)情況。適用于中小型電(dian)(dian)(dian)(dian)機(ji)、高壓電(dian)(dian)(dian)(dian)機(ji)、低壓電(dian)(dian)(dian)(dian)器(qi)等產品的(de)檢(jian)(jian)測。具有電(dian)(dian)(dian)(dian)壓、電(dian)(dian)(dian)(dian)流(liu)數(shu)字顯示、擊穿聲光報警、自(zi)動(dong)(dong)斷開高壓、手動(dong)(dong)復位、漏電(dian)(dian)(dian)(dian)流(liu)直接在高壓端測量等特點(dian)。
主要特點:
1、 廣(guang)泛(fan)應用于家用電(dian)器(qi)(qi)、電(dian)線(xian)電(dian)纜、儀(yi)器(qi)(qi)儀(yi)表等產品的超高耐壓測試、絕緣(yuan)材料的極(ji)限耐壓試驗及(ji)電(dian)聲器(qi)(qi)材的極(ji)化等
2、 天津移動式(shi)耐壓(ya)儀廠家采用軸對稱不等邊八角形外(wai)殼(ke)*結構方式(shi);可輸出雙高壓(ya)。
3、油(you)箱內油(you)面低于(yu)油(you)箱沿,避免了漏油(you)現象。
4、 接線(xian)柱在箱(xiang)蓋(gai)上(shang),避(bi)免了碰(peng)撞,提高了機(ji)械和電(dian)氣性能(neng)。
5、上海移動式耐壓儀廠家具有結構緊湊、電氣性(xing)能穩定,容(rong)量足(zu)、體積小(xiao)、重量輕、使用和維護(hu)方(fang)便等特點。
技術參數:
1、工作電壓:220V ±10% 50Hz;
2、試驗電壓連續可調:0-5KV 0-3KV 0-10KV 0-20KV 0-30KV;
3、泄漏電流設定:5mA、10mA、20mA、50mA、100mA、200mA、500mA、1000mA※;
4、變壓器容量:5KVA、3KVA、10KVA、20KVA、30KVA、50KVA、100KVA;
5、試(shi)驗時間:1S、2S、30S、60S、連續。
簡單"故障"排除:
1、電源開關打開時,控制箱上的數顯表不亮
請檢查電源連線及所有保險管,保險管若有損壞時,請按保險管座旁標注的安培數更換新管。
2、若打開電源開關,數顯表亮,高壓顯示燈(綠)不亮,加不上高壓。
① 故障顯示"回零"燈亮
沒有回零位,請逆時針轉動高壓輸出調整鈕和微調旋鈕回到零位上至"回零"燈滅,即可加高壓。
② 故障顯示"其它"燈亮有兩種現象,1、接地保護,2、斷線保護
a. 可能接地線未接好,或地線不可靠接地。請接好可靠的地線,關閉電源,重新啟動。
b.可能為連接控制箱與高壓塔的電纜未接好,接好電纜請關閉電源,重新啟動。或電纜線兩端焊接頭脫焊時會出現此故障,請焊好電纜兩端的焊頭,關閉電源,重新啟動。
C.可能控制箱內某一線頭脫焊斷開,請重新焊接好,關閉電源,重新啟動。
3、一切正常,但在未升到額定輸出電壓的 過程中保護
①故障顯示"過流"燈亮
a. 試品短路,或泄漏電流過大。
b. 大電容負載時,升壓過快。關閉電源,重新啟動,減慢升壓速度。
② 故障顯示"過壓"燈亮
過壓保護整定旋(xuan)鈕未(wei)置于zui大處(chu),請順時針旋(xuan)轉到zui大處(chu),關閉電源,重新啟動。